IDDQ TESTING OF VLSI CIRCUITS PDF

What is a Curve Trace? A curve trace is produced by an electrical test usually made by measuring the current I that results from applying a voltage V varied over a range from one voltage value to another value. The display or plot of current versus voltage obtained from this test is referred to as a curve trace or I-V measurement. Curve traces can also be V-V or V-I measurements. Two main modes can yield useful information: current vs.

Author:Nikojas Akisho
Country:Liechtenstein
Language:English (Spanish)
Genre:Travel
Published (Last):19 October 2017
Pages:298
PDF File Size:3.72 Mb
ePub File Size:13.20 Mb
ISBN:332-9-68471-714-5
Downloads:63200
Price:Free* [*Free Regsitration Required]
Uploader:Grom



What is a Curve Trace? A curve trace is produced by an electrical test usually made by measuring the current I that results from applying a voltage V varied over a range from one voltage value to another value. The display or plot of current versus voltage obtained from this test is referred to as a curve trace or I-V measurement.

Curve traces can also be V-V or V-I measurements. Two main modes can yield useful information: current vs. Current vs. Typically, an IC is placed in a low current state by tying the inputs to appropriate values logical "1" or "0" and letting the output pins float. Many ICs must be initialized i. Because power supply current can range over several orders of magnitude, take an initial measurement using a logarithmic scale for current if possible.

Once you have examined the magnitude and general shape of the curve, take the measurements using a linear scale for current. The IC is placed in the state in which the electrical failure mode is active. The voltage is set at the maximum operating voltage, and the current is monitored for changes during a period of several seconds to a minute.

Power supply current measurements can yield information that allows the analyst to determine the failure mechanism. The shape of the current and its stability give important clues to the presence of failure mechanisms such as gate oxide defects, inter-level shorts, metal stringers, and a variety of open interconnect failure mechanisms.

Plot of an IC in a high current state. Plot of an IC in a low current state. How is a Curve Trace Performed? The typical curve trace test method is to force a voltage and measure the resultant current for a single pin at a time to evaluate continuity or leakage current. The Tektronix is an analog instrument commonly used to provide a real time display of the current and voltage while the voltage continuously sweeps from a negative voltage through zero to a positive voltage and back to the negative voltage AC mode.

The HP is a digital instrument that can display the current and voltage with the voltage incrementally stepped between two values. The HP can provide both linear and logarithmic displays, save data in internal files and on floppy diskettes, and send data to other equipment, such as a plotter.

Switchbox Method The most common method for measuring the power supply current is to use a switchbox to set the IC in the desired state. Once the IC is placed in the socket, check the pins for continuity. To do this, set all switches low. Connect pin 1 to the curve tracer. Input, bi-directional, and output pins should exhibit diode characteristics in both directions.

The VDD pin s should exhibit a diode characteristic in the reverse direction only, and the VSS pin s should exhibit a diode in the forward direction only. Once continuity has been verified, place the pins in a condition to exercise the defect. At this point during the analysis, you may not have a good indication on how to do this. After locating a high current state, use the following procedures to characterize it.

If it is relatively easy to produce the high current state, sweep the voltage from the maximum rated supply voltage down to zero volts on a logarithmic scale and repeat the measurement using a linear scale. Once this has been done, reproduce the condition using the maximum rated supply voltage and measure the current with respect to time.

Measure for at least 10 seconds, and, if possible, up to 60 seconds. If the condition is difficult to reproduce, make the time measurement first and then make the current voltage sweep max. This will hopefully allow you to obtain the most data. If at all possible, repeat the process to confirm your initial measurements. ATE Method If you are unable to produce a high current state using a switchbox, you may be able to use Automatic Test Equipment to locate potential high current states. This requires a tester with a power supply current option and a vector set with the capability of halting on particular vectors and making measurements.

The test engineer for the IC may be able to help you with this activity. Methods for determining the high current state With a bench setup, you may want to try the following things: Start with the static burn-in configuration Try clocking the IC and checking after each toggle step Try toggling other pins with global influences on the IC reset, initialization, interrupt pins, etc.

Why is a Curve Trace Performed? This type of measurement is preferred rather than a measurement of current at a single voltage for several reasons, including: 1 the curve trace instrument can provide more precise control over the maximum current, voltage, or power to assure that the failure mechanism is not altered and that the component is not damaged, 2 the I-V curve can provide useful information about the stability and nature of the failure mechanism.

Another important reason for performing a power supply current curve trace is the amount of information that can be obtained quickly and non-destructively. The curve can be obtained in a manner of minutes and can yield useful information on the stability and nature of the failure mechanism.

Because of its relative ease to obtain, it is also useful as a monitor after each destructive step to determine if conditions have changed as a result of the step or technique.

When is a Curve Trace Performed? A power supply current curve trace is usually performed as one of the initial electrical measurements during analysis of a component. Power supply current measurements would typically be used first to attempt to confirm the failure symptoms.

For example, the curve can be used to confirm an IDDQ failure or standby current failure. Second, the curve can be used to determine if a functional or parametric failure has an associated high current signature. If a high current signature can be obtained, a number of rapid localization techniques can then be employed to determine the failure i. A power supply curve curve trace should also be performed after tests that can alter the current demands on the IC, such as an unbiased bake and biased temperature stressing.

The technique should also be performed after each destructive test such as delidding, top glass removal, backgrinding, and backside die thinning. The technique is a quick and easy way to determine if the destructive step altered the behavior of the IC. Equipment capable of applying prescribed voltage to the test circuit power supply terminals and measuring the resultant currents flowing in these terminals shall be provided.

The test chamber shall be capable of maintaining the device under test at any specified temperature. The device shall be stabilized at the specified test temperature.

Inputs of the device under test shall be conditioned in such a way as to provide a HIGH level at the output, the worst case supply voltage s shall be applied and the resultant current flow in the supply terminals measured. Inputs of the device under test shall be conditioned in such a way as to provide a LOW level at the output, the worst case supply voltages s shall be applied and the resultant current flow in the supply terminals measured.

The inputs of the device under test shall be conditioned to put the device into its worst case power dissipating state. The inputs of the device under test shall be exercised to put the device in a known output state either HIGH or LOW that causes worst case power dissipation.

See 3. The driving signal to the test circuit shall be provided according to Method of this standard; the worst case voltage s shall be applied and the resultant average current in the supply terminals measured. The following details shall be specified in the applicable procurement document: Test temperature. Conditioning voltages.

Dynamic input parameters see 3. Technical articles on basic electrical techniques in the proceedings, tutorials, and workshops of the International Test Conference, International Symposium for Testing and Failure Analysis, and International Reliability Physics Symposium. Gulati and C.

ASI HABLABA QUETZALCOATL PDF

Iddq testing

These circuits are usually tested as a way to find different types of manufacturing faults. Electric faults can be a major hazard and it can even lead to fatalities. This method relies on measuring the supply current Idd in its quiescent state static value of a non-switching circuit. The current that is then measured at this state is called Iddq or Idd quiescent. This testing method is based on the principle that there is no static current path between the power supply and the ground in a correctly operating quiescent CMOS digital circuit — except for a small amount of leakage.

CRANE TP410 PDF

IDDQ Testing

Iddq testing has many advantages: It is a simple and direct test that can identify physical defects. The area and design time overhead are very low. Test generation is fast. Test application time is fast since the vector sets are small.