Monitoring time, in DTS format. The OLT control board collects and summarizes the monitoring results of OLT boards with monitoring enabled, and reports the results to the server every 5 minutes. Data 2 Monitoring data records with the maximum number of lost packets and disordered packets within 5 minutes NOTE: The system generates a monitoring data record every minute. If the OLT control board reports all monitoring data to the server every 5 minutes, the service processing performance of the OLT will be affected. Therefore, the OLT control board uploads to the server a record with the maximum number of lost packets and another with the maximum number of disordered packets respectively for OLT boards and the ONT every 5 minutes.

Author:Mojin Nikozilkree
Country:Gambia
Language:English (Spanish)
Genre:Music
Published (Last):13 October 2010
Pages:336
PDF File Size:5.66 Mb
ePub File Size:19.17 Mb
ISBN:123-3-14706-751-8
Downloads:94809
Price:Free* [*Free Regsitration Required]
Uploader:Gar



Configure a DBA profile for the private line service. The value of each alarm threshold is 0 which indicates that alarms are not reported. In this example, the default alarm profile is used and no configuration is required. Add ONU 3 in offline mode.

By default, an ONU will be automatically bound to alarm profile 1 default profile. You need to manually bind an alarm profile to an ONU only when the default alarm profile does not meet requirements. In this example, the default alarm profile is used. Therefore, you do not need to manually bind an alarm profile.

Confirm the ONU status. Ensure that Control flag is active, Run State is online, and Config state is normal. If Run state is offline, a physical line may be broken or the optical module may be damaged.

Check the line and the optical module. In this case, run the display ont failed-configuration command in the diagnose mode to check the failed configuration item and the failure cause. Then, rectify the fault accordingly. If the ONU does not match, that is, Match state is mismatch, the port types and number of ports undermatch the actual port types and number of ports supported by the ONU.

In this case, run the display ont capability command to query the actual capability of the ONU, and then select one of the following modes to modify the ONU configuration: Create a proper ONU profile according to the actual capability of the ONU, and then run the ont modify command to modify the configuration data of the ONU. Then, the ONU automatically recovers the configuration successfully.